EDA 2530 Commissioning Procedure for Cable and Wireless Access
1/153 22-FGC 101 0239/2 Uen Rev J 2010-04-01
© Ericsson AB 2010
Commercial in confidence
22 (200)
2.4.4.3 32 x SHDSL Unit (02HAT00274AAE)
The 32 x SHDSL card can be equipped in slots 20 and slot 21 with up to a maximum
of two cards per subrack, providing a maximum of 64 lines. Each 32 x SHDSL card
requires its relevant Connection Unit (02HAT00136AAR) to be fitted above the 32 x
SHDSL card.
Figure 2.8 - 32 x SHDSL Unit Front Panel
The functions of the LEDs are as follows.
T (yellow) On unit normal activity
Off unit has a protecting role
Blinking configuration is being changed.
PWR (green) On unit is powered up
ALARM (red) Off normal activity
On internal alarm.
Blinking external alarm
T
PWR
RS232
02HAT 00274 AAE
SHDSL x 32
T
PWR
RS232
02HAT 00274 AAE
SHDSL x 32

Table of Contents