DSCDM errors
144
QUARTZ
OSCILLAT
Difference between the oscillator
and quartz IS too big
xxOFF
150
INITIALI
MOTOR 1
Bad measure during initialization
process when K90=1
x
K90, K91,
K98
Motor cable x OFF
151
INITIALI
MOTOR 2
Bad time measurement during
initialization process when K90=1
x
K90, K91,
K98
Motor cable x OFF
152
INITIALI
POWER OF
Error when the controller is disabled
during initialization process when
K90=1 or 2
xOFF
153
INITIALI LOW
CUR
Too low force when K90 = 6.
Increase K91
K91,
K101
xOFF
154
INITIALI
HIGH CUR
Too high force when K90 = 6.
Decrease K91
K91,
K101
xOFF
155
INITIALI LOW
TIME
Too low time when K90 = 6. Increase
K101
K91,
K101
xOFF
156
TIMEOUT
AUT CMD
Time-out during AUT command x x
K90 to
K98 K79
Motor or
encoder cable
xOFF
157
INIT BAD
PHASING
Error during the initialization
process when K90=2
xx
K90 to
K98 K79
Motor or
encoder cable
xOFF
190
SWITCH OFF
& ON
The controller has executed a save
operation (SAV command)
xOFF
M64
Displayed
message
Description Enc Mot Hrd Bad K PS TEB EBL2 Other
SW
res
Hw
res
Brk