X20/X20S and Ethos v1.5.0 User Manual
Values
Vars can hold a single fixed value (i.e. a constant) to one decimal, as per the example
above.
Each Var can hold multiple values depending upon the active conditions (such as flight
modes) configured. In the example above, the Thermal flight mode FM4 is active, so
Var1 has a value of 12.8%. When the Speed flight mode FM5 is active, Var1 will have a
value of -4.2%.
Note that a range between -10% and +15% has been set.
Actions
Vars can also be adjustable with user-definable limits, to avoid bad values potentially
causing a crash.
Vars are persistent between sessions.