26
EUROMAG | MC608 | TD210-1
www.euromag.com
8. INSERTION METERS
8.1 INTRODUCTION
The electromagnetic insertion meter MUT1222
was designed for measuring water’s velocity.
The meter can be installed in any pipe of internal
diameter between DN40 and DN1000.
The MUT1222 is designed for use in survey
applications such as leakage monitoring and
network analysis, and in permanent locations
where cost or space limitations preclude the use of
conventional full bore flowmeters.
CARE OF THE EQUIPMENT:
THE TIP OF THE MUT1222 IS
A PRECISION-BUILT PART OF
THE EQUIPMENT AND MUST
BE HANDLED WITH CARE
WHEN REMOVING/INSERTING
THE PROBE INTO THE PIPE
LINE, ENSURE THAT THE VALVE
IS FULLY OPEN, TO AVOID ANY
DAMAGE TO THE TIP AND OR
THE BODY OF THE UNIT DAMA-
GE TO THE PROBE MAY COM-
PROMISE THE FLOWMETER
AND ITS PERFORMANCES
ANY PHYSICAL DAMAGE TO
THE PROBE OF THE FLOWME-
TER INVALIDATES THE WAR-
RANTY
NOTE
8.1.1 FEATURES AND BENEFITS
“Hot Tap” capacity
- The MUT1222 can be installed quickly, easily
and conveniently without interrupting the
water flow in the pipe. The ball valve supplied
enables the meter to be inserted through a
hot tap assembly under full working pressure
conditions, without major excavations, de-
watering line, pipeline shutdown and cutting
normally required for in-line metering.
Ease of operation
- Fittings to existing guidelines of 1” without
the need for the major, expensive and time-
consuming excavations associated with full
bore meters.
- The power options of battery (MC608B) and
renewable energy (MC608R solar panel
equipped) supplies, mean MUT1222 is easy
to install and completely independent also in
the most remote environments
Integration of pressure and temperature
measurement
- In combination with MC608 converters
and the integrated pressure/temperature
measurement modules allows full control
and measurement of the most important
information in leakage control systems and in
any other water monitoring and check point.
- All data can be downloaded through the
software MC608, made available as standard.

Table of Contents

Other manuals for Euromag MC608 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Euromag MC608 Series and is the answer not in the manual?

Euromag MC608 Series Specifications

General IconGeneral
BrandEuromag
ModelMC608 Series
CategoryMedia Converter
LanguageEnglish

Related product manuals