Test Setup - Test Configurator, Timer, and System
NetBlazer 163
ISDN PRI - Call Management
Number allows to enter respectively the originator and destination
numbers. A maximum of 30 digits is permitted.
If the originator and/or destination number field is empty for any
channel, a warning icon with the following message is displayed at
the bottom of the pop-up:
Call origination settings incomplete. Missing Calling or Called
Party Number.
Call at Start check box when selected, initiates calls for the
selected channel when the test is started. Alternatively the Call All
at Start check box can be used to initiates calls for all configured
channels when the test is started.
Interface/
Rate
Switch Type Numbering Types for ... Numbering Plan
Unknown
ISDN
Telephony
Private
DS1 National ISDN Unknown International,
National, Local
Subscriber
Nortel DMS-100/250
and
AT&T 4ESS/5ESS
Unknown International,
National,
Subscriber
Subscriber
E1 Euro VN6
and
Euro ISDN
Unknown Unknown,
International,
National,
Subscriber
Unknown,
Network Specific,
Subscriber
Euro Q.SIG Unknown Unknown,
International,
National,
Subscriber
Unknown,
Level 2 Regional,
Level 1 Regional,
PISN Specific,
Level 0 Regional

Table of Contents