Test Results
NetBlazer 405
Summary (EtherSAM)
Summary (EtherSAM)
From the Test menu, tap Results, and the Summary tab.
Note: For Dual Test Set, only Start Time is displayed on the remote module.
Service Configuration/Performance Test Status indicates the actual
test status as follows:
Start Time indicates the date and time the test has been started. The
date and time is reset every time the test is restarted.
Remote unit in use and locked for Dual Test Set indicates that this
module is used for Dual Test Set as the remote module.
Test Status Description
“--” Test has not started.
Disabled Test/subtests is/are disabled.
Running Test/subtest is currently running.
Data Transfer Test/subtest is running but no test traffic is being transmitted.
Completed, <Verdict> Test/subtest has completed with the test pass/fail verdict. A
fail verdict is declared when a Link Down or LOS is detected,
or when any SLA parameter fails.
Aborted, <reason> Test/subtest has been aborted either manually (Stop) or
automatically from an alarm and the reason why the test has
been aborted is also displayed as follows:
Link down alarm, LOS alarm, Timeout during execution,
DTS connection failed, Loss of remote connection (DTS),
LOPPS-L Alarm
a
, LOPPS-R Alarm
a
,
LOPPS-L / LOPPS-R Alarm
a
, Unresolved addresses,
No test enabled, Invalid Burst Configuration,
CIR disabled for all services, Excessive Refill Time
b
,
Stopped
a. Available for Dual Test Set in One-Way Latency measurement mode.
b. An excessive refill occurs when the pre-burst and/or post-burst duration last for
more than 2 seconds.