Test Results
NetBlazer 391
Summary
Summary
Note: Available with Transport, Ethernet (EtherBERT, Through Mode, Smart
Loopback), and Wireless test applications. For other test applications see
the corresponding test summary page.
From the Test menu, tap Results, and the Summary tab.
Status indicates the actual test status as follows.
“--”: The test is not running or results are not available.
In Progress: The test is running.
Completed: The test is completed, stopped at the planned time, or
manually stopped when there is no set timer.
Start Time indicates the date and time the test has been started. The
date and time is reset every time the test is restarted or reset.
Power Recovery when displayed, indicates that the test has
automatically recovered from a power failure. The number of
occurrences is also displayed next to the Power Recovery field. Refer
to Power Failure Recovery on page 559.
Logger Full, when displayed, indicates that the logger is full. Refer to
Logger and Alarms/Errors Logger on page 362.