CheckSafetyInterlockSystem
ServiceInterval:Beforeeachuseordaily
Important:Itisessentialthatoperatorsafetymechanismsbeconnectedandinproperoperating
conditionpriortouse.
Note:Ifmachinedoesnotpassanyofthesetests,DoNotoperate.ContactanAuthorizedServiceDealer.
Note:Topreventenginecut-outsonroughterrain,theseathasa1/2secondtimedelaybeforetheengine
beginstoshutdown.
ChecktheNormalEngineStartingChart
System
ParkingBrake
PTO
MotionControl
Levers
OperatorOutcome
EngagedDisengaged
(Blades)
Bothleversout
(neutrallock)
Inseatorout
oftheseat
Startershould
crank
Engaged
Upposition,
butblades
disengaged*
Bothleversout
(neutrallock)
Inseatorout
ofseat
Startershould
crank
StateofSystem
*Note:ThestarterwillcrankwiththePTOswitchinthe“ON”(pulledup)position;however,thesystemwill
disengagethePTOandaresetPTOerrorwilloccur.EngagingthePTOwillrequiretheoperatortoresetthe
PTOswitchbyturningit“OFF”(pusheddown)andthenturningit“ON”.