DXP HD 4K PLUS Series • SIS Configuration and Control 46
X3!
= Subnet mask
nnn.nnn.nnn.nnn (255.255.0.0 = default)
X3@
= Gateway address
nnn.nnn.nnn.nnn (0.0.0.0 = default)
X3#
= MAC address
00-05-A6-xx-xx-xx
X3$
= Open connections
0-<maximum number of open connections>
X3%
= Port timeout
1 to 65000 in 10-second intervals (30 = default)
X3^
= Device name Maximum 63 alphanumeric characters or hyphens.
The first character must be an alpha character.
The last character cannot be a hyphen. No blank
or space characters are permitted. Uppercase and
lowercase letters are interchangeable.
X3&
= Date and time
In the format MM/DD/YYHH:mm:SS
MM = month: 01 (January) to 12 (December)
DD = day: 01 to 31 (depending on the month)
YY = year: 00 to 99 (last two digits)
HH = hour: 00 to 23
mm = minute: 00 to 59
SS = second: 00 to 59
X3*
= Date and time (view only)
In the format DAY,DDMMMYYYYHH:mm:SS
DAY =day of the week: Mon to Sun
DD = date: 01 to 31 (depending on the month)
MMM = month: 01 to 12
YYYY = year: 2000 to 2099
HH = hour: 00 to 23
mm = minute: 00 to 59
SS = second: 00 to 59
X3(
= GMT offset
-12:00 to +14:00
X4)
= Time zone Time zone code (see the View available time
zones command on page61 to view a list of
available time zones). The code is followed by an * in
the response.
X4!
= Time zone description
In the format (UTCX3()<Description>
This is the UTC equivalent for a particular time zone
as well as a general description of the geographical
area.
X4@
= Password 128 characters maximum
NOTES:
The pipe (|) character is invalid for passwords.
The factory configured passwords for all accounts on this device have
been set to the device serial number. In the event of a complete system
reset, the passwords revert to the default, which is no password.
X4#
= Filename
Can carry a full path name. EDID file format is .bin,
carrying 128 or 256 bytes of binary data.
X4%
= Serial port number
0199
X4^
= Baud rate
9600 (default), 19200, 38400, 115200
X4&
= Parity
Odd, Even, None (default), Mark, Space
Enter only the first letter.