EasyManua.ls Logo

Ferroli TOR - User Manual

Ferroli TOR
184 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
EN
INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE
RO
MANUAL DE UTILIZARE ȘI INSTALARE
PL
INSTRUKCJA OBSŁUGI I KONSERWACJI
HU
TELEPÍTÉSI ÉS KARBANTARTÁSI ÚTMUTA
BG
УКАЗАНИЯ ЗА МОНТАЖ И ПОДДРЪЖКА
EL
ΟΔΗΓΊΕΣ ΓΊΑ ΤΗΝ ΕΓΚΑΤΑΣΤΑΣΗ ΚΑΊ ΤΗ ΣΥΝΤΗΡΗΣΗ
IT
MANUALE DI INSTALLAZIONE E MANUTENZIONE
cod. 3542B750 - Rev 05 - 07/2022
TOR
Wall-mounted electric boiler
Cazan electric montat pe perete
Naścienny elektryczny kocioł grzewczy
Falra szerelhető elektromos kazán
Електрически водонагревателен котел със стенен монтаж
Επιτοίχιο ηλεκτρικό μπόιλερ
Caldaia murale elettrica

Table of Contents

Questions and Answers

  • D
    Derrick CraneAug 12, 2025
    What to do if there is water pressure switch fault in Ferroli TOR Boiler?
    • E
      elizabeth98Aug 12, 2025
      If the water pressure switch in your Ferroli Boiler malfunctions, it could be due to a few reasons. First, there might be water leakage in the heating circuit, in which case you should restore the water. Another cause could be disconnection or damage to the water pressure switch/sensor, so you should check the water pressure switch. Finally, the pressure sensor type might differ from the parameter P03 selection; in this case, check and modify the parameter P03.
  • K
    Katherine PetersAug 15, 2025
    Why does the safety thermostat intervene (95 °C) in my Ferroli Boiler?
    • R
      Raymond MillerAug 15, 2025
      If the safety thermostat intervenes (95 °C) in your Ferroli Boiler, it could be due to a damaged heating thermostat. Check whether the heating thermostat positioning and operation are correct. Another possible cause is that the water in the heating system isn’t circulating. In this case, check the circulating pump and remove the air from the heating system.
  • S
    stevebuckAug 20, 2025
    How to fix heating temperature sensor fault in Ferroli TOR Boiler?
    • T
      Tara ConnerAug 20, 2025
      If you're experiencing a heating temperature sensor fault with your Ferroli Boiler, it could be due to an open circuit, a short circuit, or a loose connecting line. To resolve this, check the connection or replace the temperature sensor.
  • R
    Ryan WardAug 23, 2025
    What to do if the heater temperature exceeds 90°C in Ferroli TOR?
    • M
      Maria Williams DVMAug 23, 2025
      If the heater temperature exceeds 90 °C in your Ferroli Boiler, it might be because the water in the heating system isn’t circulating properly. To fix this, check the circulating pump and remove any air from the heating system.
  • B
    brent52Aug 27, 2025
    Why is there too big temperature gradient in Ferroli Boiler?
    • L
      lmorganAug 27, 2025
      A large temperature gradient in your Ferroli Boiler can be caused by a couple of things. It might be due to water leakage in the heating circuit, so you should inject water into the system. Alternatively, the pump could be blocked, so check the circulation of the pump.
  • B
    Brandon LopezAug 31, 2025
    How to troubleshoot outdoor temperature sensor fault in Ferroli TOR Boiler?
    • T
      Thomas HartmanAug 31, 2025
      If you encounter an outdoor temperature sensor fault in your Ferroli Boiler, it could stem from an open circuit, a short circuit, or a loose connecting line. Inspect the connection or replace the temperature sensor to resolve this issue.
  • L
    lopezpatriciaSep 3, 2025
    What causes water tank temperature sensor fault in Ferroli TOR?
    • M
      Michael WhiteSep 3, 2025
      If you have a water tank temperature sensor fault with your Ferroli Boiler, the issue might be an open circuit, a short circuit, or a loose connection to the water tank NTC. Check the connection or replace the temperature sensor.
  • H
    Hannah WhiteSep 7, 2025
    What to do if Ferroli Boiler doesn't detect temperature sensor?
    • J
      Jason HallSep 8, 2025
      If your Ferroli Boiler isn't detecting the temperature sensor, it's possible that the heating temperature sensor has fallen off or is damaged. Check whether the heating temperature sensor has fallen off, and if so, reposition it, or replace it if damaged.

Ferroli TOR Specifications

General IconGeneral
MountingWall-mounted
Warranty2 years
FuelNatural Gas
Dimensions (HxWxD)700 x 400 mm
Water Pressure0.8 - 3 bar

Related product manuals