EasyManua.ls Logo

Festo CMSH - Page 74

Festo CMSH
84 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
74
Festo — CMSH — 2021-10
Malfunctions
ID Message NAM
UR
1)
Possible cause Notes/remedies
1299 Initialization failed:
Incorrect potentiom-
eter value
–
Drive outside the oper-
ating range of the potenti-
ometer
–
Check whether the posi-
tioner is correctly mounted
on the drive.
–
With external potentiom-
eter: check attachment
position of the potentiom-
eter.
1300 Short circuit: Potenti-
ometer
–
Short-circuited potentiom-
eter
–
Check connection of the
external potentiometer.
1301 Incorrect value:
Potentiometer
–
Drive outside the oper-
ating range of the potenti-
ometer
–
Check whether the posi-
tioner is correctly mounted
on the drive.
–
With external potentiom-
eter: check attachment
position of the potentiom-
eter.
1302 Incorrect value:
Potentiometer
–
Drive outside the oper-
ating range of the potenti-
ometer
–
Check whether the posi-
tioner is correctly mounted
on the drive.
–
With external potentiom-
eter: check attachment
position of the potentiom-
eter.