74
Festo — CMSH — 2021-10
Malfunctions
ID Message NAM
UR
1)
Possible cause Notes/remedies
1299 Initialization failed:
Incorrect potentiom-
eter value
Drive outside the oper-
ating range of the potenti-
ometer
Check whether the posi-
tioner is correctly mounted
on the drive.
With external potentiom-
eter: check attachment
position of the potentiom-
eter.
1300 Short circuit: Potenti-
ometer
Short-circuited potentiom-
eter
Check connection of the
external potentiometer.
1301 Incorrect value:
Potentiometer
Drive outside the oper-
ating range of the potenti-
ometer
Check whether the posi-
tioner is correctly mounted
on the drive.
With external potentiom-
eter: check attachment
position of the potentiom-
eter.
1302 Incorrect value:
Potentiometer
Drive outside the oper-
ating range of the potenti-
ometer
Check whether the posi-
tioner is correctly mounted
on the drive.
With external potentiom-
eter: check attachment
position of the potentiom-
eter.