Festo — CMSH — 2021-10
Malfunctions
75
ID Message NAM
UR
1)
Possible cause Notes/remedies
1310 Initialization failed:
Potentiometer failure
Increased sensor noise
Drive outside the oper-
ating range of the potenti-
ometer
Defective potentiometer
External potentiometer
outside specification
Compressed air leakage at
the drive or positioner
Incorrect or missing pneu-
matic connection of the
drive
Incorrect configuration of
the safety position
Repeat initialisation.
If the initialisation
fails repeatedly, con-
tact Festo Support
è
www.festo.com/sp.
Check whether the posi-
tioner is correctly mounted
on the drive.
With external potentiom-
eter: check attachment
position of the potentiom-
eter.
Check specification of the
external potentiometer.
Check pneumatic connec-
tion.
Check configuration of the
safety position.
1320 Initialization failed:
Position sensing
Increased sensor noise
Drive outside the oper-
ating range of the potenti-
ometer
Defective potentiometer
External potentiometer
outside specification
Compressed air leakage at
the drive or positioner
Incorrect or missing pneu-
matic connection of the
drive
Incorrect configuration of
the safety position
Repeat initialisation.
If the initialisation
fails repeatedly, con-
tact Festo Support
è
www.festo.com/sp.
Check whether the posi-
tioner is correctly mounted
on the drive.
With external potentiom-
eter: check attachment
position of the potentiom-
eter.
Check specification of the
external potentiometer.
Check pneumatic connec-
tion.
Check configuration of the
safety position.