3 Mounting and installation
Festo – MPAL-VI-EN – 2017-07a – English 55
Installing unthreaded cartridges
1. Select the cartridge èTab. 3.1.
2. Press cartridge up to the stop in the port and turn it.
3. Press and hold down cartridge in this position.
4. Insert wire clamp in the retaining groove:
– With sub-bases: from above or below
– With supply modules: from above
– With exhaust plates on supply modules: from below
5. Slide wire clamps over the detent lugs èFig. 3.5.
6. Check that the cartridge is firmly seated.
Replacing unthreaded cartridges
1. If the wire clamps on the cartridges are concealed by valves, remove the valves.
With supply modules: unfasten screws on the exhaust plate or the cover plate of the silencer.
Remove the upper part.
2. Using a narrow slotted screwdriver, lever the wire clamp over the detent lugs and remove it.
3. Remove the wire clamp.
4. Remove the old cartridge.
5. Install a new cartridge.