Commissioning
© Festo Didactic GmbH & Co. • MPS 23
Please check the adjustment of all sensors, the mechanical components and the
pneumatical components of your station to prepare the test of the whole process.
Check also the cable connectionsand the power- and air-supply.
Information
To find out the function and location of the sensors and pneumatical components
please use the technical documentation. The inputs can also be checked directly at
the PLC-LED´s. To move pneumatic actuators, please switch off the air-pressure and
move them manually by hand. Please be very careful, move the actuators back
before switching on the air-pressure again. Some pneumatic and the electrical
actuators can not be moved in this way-the pneumatic components can be activated
by the manual detection button on the valve (see picture)
Instructor:show the participants how to find out an input and an output using the
wiring diagrams. Show them why some actuators can not be moved by hand even
without air- and power supply (DC-motors and 5/3-way valves) using the
pneumatic plan to explain. Show them an example how to adjust a sensor to
define the back or front position of a cylinder and how to adjust the speed of a
pneumatical actuator. Provide the necessary tools.
Deadjust the following sensors and mechanical components (bold)
1.6 Commissioning –
Adjustment of the
Station expanded