EasyManua.ls Logo

Fimap MXR - Alarm Table

Fimap MXR
83 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6.6 Alarm Table
6.6.1 Alarms
Alarms of Overcurrent and Temperature
Id Alarm Meaning Solution
AL 1: Function
Brushes Ammeter
Brush Amperometric Protection Check consumption of the brush motor. Detected high current
on brush motor.
AL 2: Function
Vacuum Ammeter
Vacuum Amperometric Protec-
tion
Check consumption of the vacuum motor. Detected high cur-
rent on vacuum motor.
AL 3: Function
Powerstage fail
Damage of Power Damage power of brush or vacuum: replace the main card.
AL 4: Function
Overcurrent
Output overcurrent on brush or
vacuum
Detect a shortcircuit on output brush motor or vacuum motor:
Check connections and motors.
AL 5: Function
Overtemperature
Thermal protection on
brush/vacuum
Overtemperature of brush/vacuum motor: check consump-
tion of motors.
Traction Alarms
Id Alarm Meaning Solution
AL 13: Traction
Pedal Damage
Pedal Anomaly Check the connections and the status of the pedal potentiome-
ter.
AL 14: Traction
Release Pedal
Pedal pressed before starting Detected Pedal microswitch pressed before starting : release
the Pedal.
AL 15: Traction
Overtemperature
Thermal protection on traction Overtemperature on traction : check consumption of traction
motor.
AL 16: Traction
Powerstage fail
Power of traction damage Replace the main card.
AL 17: Traction
Overcurrent
Traction Overcurrent Detected a shortcircuit on the traction motor output: Check
connections and traction motor.
AL 18: Traction
Traction Ammeter
Traction Amperometric protec-
tion
Check how the traction function is used. Detected too high
working current on traction motor.
AL 19: Traction
Electrobrake
Electrobrake not inserted Check the condition of the electrobrake and its related mi-
croswitch.
General Alarms
Id Alarm Meaning Solution
AL 20: General
EEPROM FAIL
Error reading internal memory Replace the main card.
AL 21: General
KEY-OFF FAILURE
Error key sequence Error on key signal: Check the key connection. Check, also,
the batteries connections and main card
AL 22: General
Main relay fail
Damage of general relay Check the traction motor connections. If the connection are
OK, the general relay on the main card is damaged: replace
the main card.
AL 23: General
Overvoltage
Overvoltage Detected a overvoltage on the main card. Check the batteries
connections.
AL 24: Traction
Batt.connection
Battery not connected to the
main card
Check battery functioning and connection to the main card.
AL 25: General
Keyboard com.
No communication between con-
trol card and main card
Check the connections between control card and main card.