Chapter 3
Trouble-shooting for the most common
anomalies
3.1 Electrical system: what to do if. . .
The machine doesn’t switch on
1. The emergency button is pressed Release the emergency button.
2. The key is in position 0 Rotate the key in position I.
3. The key switch is not properly con-
nected
Restore the proper connections.
4. The key switch doesn’t work Replace the key switch (see section 5.1.1
at page 22).
5. The machine is not supplied Check the proper section (see section 3.1
at page 11).
The display shows an alarm message
1. The display shows an alarm mes-
sage
Check what alarm message is
shown and solve the related issue
by following the proper instructions
(see section 6.6.1 at page 49).
The machine has a very limited working autonomy
1. The BDI (Battery Discharge Indica-
tor) is not properly adjusted
Verify the type of battery used on
the machine and adjust properly the
BDI (see section 6.7.1 at page 50).
2. Batteries have been working for
several cycles
Replace the batteries.