Table 4: APPLICABLE BULLETINS
Programmers, Non-recycle Operation
Programmers, Recycle Operation
Programmers, Non-modulating
Wiring base installation, 60-2812-1
Wiring base installation, 60-2814-1
ORDERING INFORMATION
Table 5:
BurnerLogix Chassis/Flame Amplifier Module
120 VAC input with UV non-self-check amplifier
120 VAC input with UV self-check amplifier
120 VAC input with IR auto-check amplifier
120 VAC input with IR auto-check amplifier (special application only -consult factory)
120 VAC input with flame rectification amplifier
120 VAC input with direct coupled amplifier
230 VAC input with UV non-self-check amplifier
230 VAC input with UV self-check amplifier
230 VAC input with IR auto-check amplifier
230 VAC input with IR auto check (special application only-consult factory)
230VAC input with flame rectification amplifier
230VAC input with direct coupled amplifier
Table 6: PROGRAMMER MODULES
BurnerLogix Programmer Modules
Keypad selectable parameters, non-recycle operation, modulation, open damper proving, 4 second FFRT
Keypad selectable parameters, non-recycle operation, modulation, open damper proving, 2 second FFRT
Keypad selectable parameters, non-recycle operation, modulation, open damper proving, 1 second FFRT
Keypad selectable parameters, non-recycle operation, modulation, open damper proving, 1 second FFRT
Keypad selectable parameters, non-recycle operation, modulation, open damper proving, indefinite pilot hold, revert to
pilot from auto, 1 second FFRT
Keypad selectable parameters, non-recycle operation, modulation, open damper proving, voltage on terminal 16 is indefinite pilot
hold during light-off, applied voltage on term 16 is revert to pilot from auto, 4 second FFRT
Same as YP138, except, removal of voltage on terminal 16 will suspend pilot hold during light-off sequence. Terminal W used
for purge complete.
Keypad selectable parameters, recycle operation, modulation, 4 second FFRT
Keypad selectable parameters, recycle operation, modulation, 2 second FFRT
Keypad selectable parameters, recycle operation, low fire start, early spark termination, 4 second FFRT
Keypad selectable parameters, recycle operation, low fire start, early spark termination, 2 second FFRT
Keypad selectable parameters, non-recycle operation, modulation, open damper proving, fuel selection switch, valve proving,
low gas pressure check (active high), Burner On/Off through Keypad, 4 second FFRT.
Same as YP148, except low gas pressure check (active low).
Note: All programmers: when used with the YB110DC or YB230DC, the FFRT is 0.3 seconds