–48–
✱
27 POWERLINE CARRIER DEVICE (X-10) HOUSE ID ÊÊ0Ê
Powerline Carrier devices require a House ID. This field identifies
this House ID to the control.
If Powerline Carrier devices are used, they are selected in field
✱
80.
House ID is entered in following manner:
0 = A, 1 = B, 2 =C, 3 = D, 4 = E, 5 = F, 6 = G, 7 = H, 8 = I, 9 = J,
# + 10 = K, # + 11 = L, # + 12 = M, # + 13 = N, # + 14 = O, # + 15 = P.
✱
28 PHONE MODULE ACCESS CODE ÊÊ0Ê|Ê0ÊÊ
1-9 = first digit of access code
✱
or # = second digit of access code (enter # +11 for "
✱
", or # +12 for "#")
The use of a FA4285 Phone Module (can be used in Partition 1 only)
requires a 2-digit code.
Example: If desired access code is 7
✱
, 7 is the first entry, and # + 11
(for
✱
) is the second entry.
NOTE: A Ò0Ó in either digit disables the Phone Module.
✱
29 OUTPUT TO LONG RANGE RADIO (No. 7720PLUS/7820) ÊÊ0ÊÊ
If output to LRR is selected here, all messages that are programmed
to go to the primary telephone line receiver will also be sent to the
7720 PLUS or 7820 radio. These messages will always be in Contact
ID format (not affected by entry in field
✱
48). The data line is
supervised as well as certain functions in the radio. If
communication is lost or a trouble develops, a message will be
attempted to be sent via both radio and telephone to the central
station.
Note: Normal trouble restore report (
✱
71) is sent on restore of the
condition.
Entry is first digit of Trouble Dialer Report; enter Trouble code 1Ð9,
B (# +11), C (# +12), D (# +13), E (# +14), or F (# +15). The 2nd digit
of Trouble Dialer Report is automatically the 2nd digit from field
✱
60.
UL installations: must be 0 (Long Range Radio disabled)
Note: The Radio should be programmed for device address 3 on the
keypad lines.
✱
31 SINGLE ALARM SOUNDING PER ZONE (per armed period) ÊÊ0ÊÊ
0 = no limit on alarm sounding per zone
1 = limit alarm sounding to once per arming period for a given zone.
UL installations: must be 0 (no limit)
✱
32 FIRE SOUNDER TIMEOUT ÊÊ0ÊÊ
0 = yes, fire sounder timeout after time programmed in field *33
1 = no fire sounder timeout; continue sounding until manually turned
off
This control complies with NFPA requirements for temporal pulse
sounding of fire notification appliances.
Temporal pulse sounding for a fire alarm consists of the following:
3 pulses Ð pause Ð 3 pulses Ð pause Ð 3 pulses. . .