EasyManuals Logo

First Alert FA162C Installation Instructions

First Alert FA162C
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #50 background imageLoading...
Page #50 background image
–50–
DIALER
PROGRAMMING
(
40Ð
50)
40 PABX ACCESS CODE (See Box at Left) ÊÊÊÊ|ÊÊÊ|ÊÊÊÊ|ÊÊÊÊ|ÊÊÊ|ÊÊÊÊ
Enter up to 6 digits if PABX is needed to access an outside line. If
fewer than 6 digits are needed to be entered, exit by pressing [
] and
next field number (e.g., 41). To clear entries from field, press
40
.
Fields
40,
41,
42:
Enter up to the number
of digits shown. Do not
fill unused spaces.
Enter 0Ð9,
# + 11 for Ô
Õ
# + 12 for Ô#Õ
# + 13 for a pause
(2 seconds)
41 PRIMARY PHONE No. (See Box at Left)
ÊÊÊÊ|ÊÊÊ|ÊÊÊ|ÊÊÊ|ÊÊÊ|ÊÊÊ|ÊÊÊ|ÊÊÊ|ÊÊÊ|ÊÊÊ|ÊÊÊ|ÊÊÊ|ÊÊÊ|ÊÊÊ|ÊÊÊ|ÊÊÊ Ê
Enter up to 16 digits. If fewer than 16 digits entered, exit by pressing
[
]
and next field number (e.g., 42). To clear entries from field, press
41
.
Note: ÊBack-up reporting (8 calls are made to the secondary phone
number if no kiss-off is received after 8 attempts to the primary
number) is automatic only if there is a secondary phone number (field
42).
42 SECONDARY PHONE No. (See Box at Left)
ÊÊÊÊ|ÊÊÊ|ÊÊÊ|ÊÊÊ|ÊÊÊ|ÊÊÊ|ÊÊÊ|ÊÊÊ|ÊÊÊ|ÊÊÊ|ÊÊÊ|ÊÊÊ|ÊÊÊ|ÊÊÊ|ÊÊÊ|ÊÊÊ Ê
Enter up to 16 digits. If fewer than 16 digits entered, exit by pressing
[
]
and next field number (e.g., 43). To clear entries from field, press
42
. See back-up reporting note for field *41. If using the pager
feature, enter the pager phone number here.
For Fields
43,
44,
45,
and
46:
Enter digits 0Ð9; # +11=B; #
+12=C; # +13=D; # +14=E; or
# +15=F.
Enter [
]
as the fourth digit if
a 3-digit account number (for
3+1 dialer reporting format)
is used. Enter 0 as the first
digit of a 4-digit account
number for Nos. 0000Ð0999.
Exit field by pressing [
]
(and
press next field number) if
only 3 digits are used.
To clear entries from field,
press
43
,
44
,
45
or
46
.
See blank Programming Form
for examples of Account No.
entries.
If using the paging feature, do
not enter a leading 0 in the
subscriber account number,
and do not use digits A-F
anywhere in the number.
Some paging systems provide
voice mail capability, which is
activated by a leading 0 in the
message.
43 PRIMARY SUBS ACCOUNT. No. (partition 1) ÊÊÊÊ|ÊÊÊ|ÊÊÊÊ|ÊÊÊÊ
See box at left.
44 SECONDARY SUBS ACCOUNT. No. (partition 1) Ê ÊÊÊÊ|ÊÊÊ|ÊÊÊÊ|ÊÊÊÊ
See box at left.
45 PRIMARY SUBS ACCOUNT. No. (partition 2) ÊÊÊÊ|ÊÊÊ|ÊÊÊÊ|ÊÊÊÊ
See box at left.
46 SECONDARY SUBS ACCOUNT. No. (part. 2) Ê ÊÊÊÊ|ÊÊÊ|ÊÊÊÊ|ÊÊÊÊ
See box at left.
47 PHONE SYSTEM SELECT ÊÊ1ÊÊ
If Central Station Receiver is not on WATS line:
0 = Pulse Dial
1 = Tone Dial
If Central Station Receiver is on WATS line:
2 = Pulse Dial
3 = Tone Dial
48 REPORT FORMAT Ê ÊÊ7Ê Ê ÊÊ0ÊÊ
0 = 3+1; 4+1 ADEMCO Low Speed Standard Prim. Sec.
1 = 3+1; 4+1 Radionics Standard
2 = 4+2 ADEMCO Low Speed Standard
3 = 4+2 Radionics Standard
6 = 4+2 ADEMCO Express
7 = ADEMCO Contact ID Reporting
8 = 3+1; 4+1 ADEMCO Low Speed Expanded
9 = 3+1; 4+1 Radionics Expanded
Enter
as the 4th digit of
43 through
46, if 3+1 dialer reporting is
to be used.
For an explanation of these formats, see the SYSTEM
COMMUNICATION section.
Note: The maximum number of alarm and alarm restore reports
during one armed period is determined by field
93.

Table of Contents

Other manuals for First Alert FA162C