EasyManua.ls Logo

flamco LogoMatic G2 User Manual

flamco LogoMatic G2
50 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
www.flamcogroup.com/manuals
LogoMatic G2
ENG Installation and operating instructions
UC / MC/ MC-UC, electronically controlled, app-controlled
S-/M-/L-line as complete or ready-to-use stations
Question and Answer IconNeed help?

Do you have a question about the flamco LogoMatic G2 and is the answer not in the manual?

flamco LogoMatic G2 Specifications

General IconGeneral
Brandflamco
ModelLogoMatic G2
CategoryIndustrial Equipment
LanguageEnglish

Summary

Safety Instructions and Regulations

General Handling and Target Audience

Guidelines for safe operation, accessibility of instructions, and identification of authorized personnel.

Applicable Regulations and Standards

Lists statutory accident prevention, environmental protection, and specific industry standards like DIN, EN, VDE.

Intended Use and System Parameters

Permitted Application and Deviations

Defines the station's purpose for heat transfer and prohibits any unintended use causing hazards.

Heating and Sanitary System Specifications

Details permissible pressure ratings, operating temperatures, and pressures for heating and sanitary systems.

Device Identification and Usage Guidelines

Improper Use Warnings and Prohibitions

Warns against modifying the device and lists specific disallowed actions like using wrong liquids or operating without instructions.

Product Designation and Manufacturer

States the product name, function, type, and manufacturer of the LogoMatic G2 unit.

Hazard Information and Risk Mitigation

Key Hazards: Scalding and Electrical Shock

Highlights risks of scalding from hot water and electrical shock, emphasizing qualified personnel and precautions.

Operational Procedures and Engineer Requirements

Breakdown, Leaks, and Spare Parts

Procedures for handling breakdowns/leaks and guidelines for using specified spare and wear parts.

Qualifications for Trained Engineers

Defines the technical training, experience, and skills required for personnel performing work on the system.

Functional Description of LogoMatic G2

Heating and Hot Water Preparation

Explains the station's function in heating and domestic hot water preparation using a plate heat exchanger and continuous flow.

Article Numbers for Prefabricated Stations

Decoding Article Number Keys

Explains the structure of article numbers based on heating type, performance class, and domestic water circulation variants.

Technical Data and Application Limits

Dimensions, Outputs, and Operational Limits

Covers physical dimensions, heating/hot water outputs, and application limits for temperature and pressure.

Design and Component Identification

Component Legend and Descriptions

Lists and describes the function of various numbered components within the LogoMatic G2 station, shown in diagrams.

Installation Guidelines and Base Plates

Base Plate Dimensions for Wall Mounting

Provides dimensional drawings for base plates for insulated and steel variants for surface-mounted installations.

Insulated Surface-Mounted Variant Installation

Dimensions of SM Insulation and Retaining Plate

Details dimensions for the SM thermal insulation and retaining plate for surface-mounted variants.

Construction and Installation Step-by-Step

Wall Mounting and Connection Sequence

Outlines the sequence for attaching the retaining plate, hanging the station, and making hydraulic/electrical connections.

Individual Station Components: Heat Meter

Procedure for Optional Heat Meter Installation

Provides a step-by-step guide for installing an optional heat meter into the station, including safety warnings.

Individual Station Components: Cold Water Meter

Procedure for Cold Water Meter Installation

Details the procedure for installing an optional cold water meter on the station, including safety warnings.

Individual Station Components: Zone Valve

Setting the Heating Circuit Zone Valve

Explains how to set the zone valve for the heating circuit, including presetting options and reference diagrams.

Optional Safety Temperature Limiter (STL)

STL Technical Data and Installation Steps

Provides technical data and installation steps for the optional Safety Temperature Limiter (STL) and its actuator.

Dirt Trap and Thermostatic Circulation Bridge

Component Function and Adjustment

Describes the function of the dirt trap and thermostatic circulation bridge, including adjustment ranges and flushing procedures.

Differential Pressure Regulator Functionality

Setting the DP Regulator Valve

Explains how to adjust the differential pressure regulator and provides valve settings based on rotations and pressure.

Control Valves Operation and Function

Role of Control Valves X and Y

Details the function of control valves X and Y in managing domestic water heating priority and secondary heating circuit supply.

Mixed Heating Circuit Configuration

MC Variant for Underfloor Heating

Describes the configuration for MC variants, focusing on the mixing circuit as an injection system with HE pump and zone valve.

High-Efficiency Heating Circuit Pump Details

GF UPM3 Hybrid Pump Specifications

Provides technical data, electrical specifications, and performance characteristics for the GF UPM3 Hybrid pump.

Hot Water Throttle Functionality

Throttle Plate Identification and Use

Explains the hot water throttle on S- and M-Lines and the color coding of available throttle plates.

Domestic Water Circulation System

Pump, Backflow Preventer, and Operation

Details the domestic water circulation system, including the pump, backflow preventer, and operational requirements.

Optional Accessories for LogoMatic G2

Heating Circuit Manifold Examples

Illustrates heating circuit manifolds and lists other optional accessories like hoods and thermal insulation.

Underfloor Heating System Components

UFH Manifold and Terminal Strip Information

Provides details on underfloor heating manifolds and prewired UFH terminal strips, including article numbers.

Static Heating Circuit Extension Options

MC-UC Variants for Static Heating

Shows sample depictions of extending static heating circuits with MC-UC variants and relevant extension article numbers.

Ball Valves and Mounting Rail Accessories

DN 20 Straight Ball Valve Sets

Details DN 20 straight ball valve sets (BV), including article numbers and installation notes.

Mounting Rails with Ball Valves (FFR)

Describes two variants of mounting rails with ball valves (FFR) and their respective article numbers for installation.

Cover Hoods and Cladding Housing Options

Surface-Mounted (SM) Hood Overview

Provides an overview of SM hoods, their dimensions, notes, and article numbers for various configurations.

Flush-Mounted (FM) Hood Installation Details

FM Hood Dimensions and Variants

Details installation dimensions for FM hoods, including panel dimensions, height adjustability, and article numbers.

Complete Station Sample Configurations

LM G2 SI/SM Variant Configurations

Presents sample configurations for LM G2 SI/SM variants, showing article numbers for different PHE types and components.

Commissioning and Initial Start-up

System Flushing, Filling, and Bleeding

Provides instructions for flushing, filling, and bleeding the system prior to commissioning, with notes for installers.

Initial Start-up and Controller Setup

Details the initial start-up process, controller connection, and observation of settings for optimal operation.

Maintenance and Service Procedures

Water Quality and Scaling Prevention

Discusses domestic water hardness impact on scaling and provides guidelines for preventing limescale deposits and corrosion.

Pressure Loss Characteristic Curves

Hot Water Section Pressure Loss Analysis

Presents pressure loss curves for the hot water section based on domestic water draw-off rate for S-, M-, and L-Lines.

Troubleshooting and Fault Diagnosis

Systematic Fault Location Steps

Provides a systematic overview of checks to help locate and diagnose common faults within the system.

Spare Parts Listing: Valves and Meters

Zone Valves, Mut Valves, and Flow Meters

Lists spare parts for valves, flow meters, and sensor packages with corresponding article numbers.

Spare Parts Listing: Pumps and Controllers

Pumps, STM, DPCV, and Seal Packages

Lists spare parts for pumps, STM, DPCV, and seal packages with corresponding article numbers.

Related product manuals