EasyManua.ls Logo

Flexim FLUXUS H721 - Page 40

Flexim FLUXUS H721
229 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 Mounting
6.2 Transducers FLUXUS H721
2022-05-15, UMFLUXUS_H721V1-5EN
40
Place the tension strap around the pipe and insert it into the clasp (see Fig. 6.19).
Tighten the tension strap.
Tighten the clasp screw.
Ratchet clasp
Insert the tension strap into its clamp and the metal spring (see Fig. 6.21).
The metal spring does not have to be mounted on:
steel pipes
pipes with an outer diameter < 80 mm
pipes that are not subjected to significant temperature fluctuations
Position the ratchet clasp, tension strap clamp and metal spring (if necessary) on the pipe (see Fig. 6.17):
On a horizontal pipe, mount the tension strap clamp laterally to the pipe, if possible.
Mount the metal spring (if necessary) opposite the tension strap clamp.
Place the tension strap around the pipe and pass it through the slot of the clasp screw (see Fig. 6.22).
Tighten the tension strap.
Cut off the protruding tension strap (see Fig. 6.22).
Tighten the clasp screw.
Fig. 6.18: Tension strap with clamp Fig. 6.19: Tension strap with quick release
clasp and metal spring
1 tension strap clamp 1 clasp screw
2–metal spring
Fig. 6.20: Tension strap with band clamp
clasp
1 clasp screw
Caution!
The edge of the tension strap is very sharp.
Risk of injury.
Debur sharp edges.
Wear the required personal protective equipment.
Observe the applicable rules.
Notice!
In order to release the screw and the tension strap, press the lever down (see Fig. 6.22).
1
2
1
1

Table of Contents