6 Mounting
FLUXUS H721 6.2 Transducers
47
UMFLUXUS_H721V1-5EN, 2022-05-15
Mounting
When measuring in reflection arrangement, 1 transducer mounting fixture is mounted laterally on the pipe.
When measuring in diagonal arrangement, 2 transducer mounting fixtures are mounted on opposite sides of the pipe.
In the following, the installation of 1 transducer mounting fixture in reflection arrangement is described.
Overview of the mounting steps
step 1
disassembly of the transducer mounting fixture Variofix C
step 2
fixation of the clasps to the tension straps
step 3
fixation of the tension strap to the pipe
step 4
fixation of the rail to the pipe
step 5
installation of the transducers in the transducer mounting fixture Variofix C
Step 1: Disassembly of the transducer mounting fixture Variofix C
Disassemble the transducer mounting fixture Variofix C.
In order to remove the cover from the rail, bend the outer sides of the cover outwards.
In order to remove the spring clip from the rail, slide it over the indentations on the rail and lift it off.
Fig. 6.34: Transducer mounting fixture
Variofix C (reflection arrangement)
Fig. 6.35: Transducer mounting fixture
Variofix C (diagonal arrangement)
Fig. 6.36: Removal of the cover