Table 13.6 Capacitance
Function
Range
Accuracy
Capacitance
1 μF to 1000 μF
±(1.0% + 4 dgt)
Overload protection: 1000 V
(rms)
.
Table 13.7 Flex Clamp Adaptor Function
Function
Range
Accuracy
Flex (ACA)
30.00 A
±(1% + 5 dgt) 45 ~ 400Hz
300.0 A
3000 A
LCD displays ‘0’ counts when the reading is < 10 counts
Additional accuracy for the Flex function is listed in the FLIR clamp adaptor User Manuals (Models
TA72_TA74).
Table 13.8 Flex Clamp Adaptor Function (Frequency)
Function
Range
Accuracy
Frequency (Flex)
600.0 Hz
±(0.1% + 2 dgt)
6.000 kHz
10.00 kHz
Sensitivity:
Flex function:
> 3A (rms) at 30.00A range for 10Hz ~ 1kHz
> 30A (rms) at 300.0A range for 10Hz ~ 1kHz
> 300A (rms) at 3000A range for 10Hz ~ 1kHz
Hz function at Flex rotary switch:
> 3A (rms) for 10Hz ~ 10kHz
> 6A (rms) for 10kHz ~ 60kHz
Work Lights
Color Temperature: 4000-5000°K
Beam Angle: ± 20°
Light Output: 70 lumens, minimum
Power: 0.5 Watt RMS