FLIRCM85USERMANUALDocumentIdentifier:CM85‐en‐US_AB
32
Table7.10Resistanceandcontinuityanddiode
Function Range Accuracy
Resistance
999.9Ω ±(1.0%+5dgt)
9.999kΩ
±(1.0%+3dgt)
99.99kΩ
Continuity 999.9Ω ±(1.0%+5dgt)
Diode 0.40–0.80V ±0.1V
Overloadprotection:1000V
rms
.
Maximumtestcurrent:Approx.0.5mA.
MaximumopencircuitvoltageforΩ:Approx.2.4V.
Maximumopencircuitvoltagefordiode:Approx.±1.6V.
Continuitythreshold:
<30Ωbeepon.
>100Ωbeepoff.
Continuityindicator:2kHztonebuzzer.
Continuityresponsetime:<100ms.
Table
7.11Capacitance
Function Range Accuracy
Capacitance
3.999μF
±(1.9%+8dgt)
39.99μF
399.9μF
3.999mF
Overloadprotection:1000V
rms
.