Technical data26
Image presentation modes
Image modes Thermal, thermal MSX, picture in picture, digital
camera
Infrared image Full color infrared image
Visual image Full color visual image
Multi Spectral Dynamic Imaging (MSX)
Thermal image with enhanced detail presentation
Picture in Picture Resizable and movable infrared area on the visual
image
Gallery
Review thumbnail/full image on the camera
Edit measurements/palettes/image modes on
the camera
Measurement
Object temperature range Accuracy
–40 to +150°C (–40 to +302°F) –40 to +5°C (–40 to +41°F) ±2°C (±3.6°F)
+5 to +100°C (+41 to +212°F) ±1°C (±1.8°F)
+100 to +150°C (+212 to +302°
F)
±1%
0 to +650°C (+32 to +1202°F) 0 to +100°C (+32 to +212°F) ±2°C (±3.6°F)
+100 to + 650°C (+212 to
+1202°F)
±2%
+300 to +2000°C (+572 to
+3632°F)
+300 to +2000°C (+572 to
+3632°F)
±2%
NOTE
For HSI use, above 30 Hz frame rate, the typical accuracy will be ±2.5°C (±4.5°F), or 2.5% of read-
ing @ 25°C (77°F).
Measurement analysis
Spotmeter
10
Area
5 + 5 areas (boxes and circles) with max./min./
average
Profile 1 line profile with max./min. temperature
Automatic hot/cold detection
Auto hot or cold spotmeter markers within the
area and profile
Measurement presets No measurements, Center spot, Hot spot, Cold
spot, User preset 1, User preset 2
User presets The user can select and combine measurements
from any number of spots/boxes/circles/profiles/
delta
Difference temperature Delta temperature between the measurement
functions and the reference temperature
Reference temperature Manually set using the difference temperature
Atmospheric transmission correction Automatic, based on the inputs for distance, at-
mospheric temperature, and relative humidity
Optics transmission correction Automatic, based on signals from internal sensors
Emissivity correction Variable from 0.01 to 1.0 or selected from the ma-
terials list
Reflected apparent temperature correction Automatic, based on the input of the reflected
temperature
External optics/windows correction Automatic, based on the inputs of the window
transmission and temperature
#T559954; r. AP/42311/42335; en-US
92

Table of Contents

Other manuals for FLIR T10 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FLIR T10 Series and is the answer not in the manual?

FLIR T10 Series Specifications

General IconGeneral
BrandFLIR
ModelT10 Series
CategoryThermal cameras
LanguageEnglish

Related product manuals