Theory of thermography
38
38.4 Infrared semi-transparent materials
Consider now a non-metallic, semi-transparent body let us say, in the form of a thick flat
plate of plastic material. When the plate is heated, radiation generated within its volume
must work its way toward the surfaces through the material in which it is partially ab-
sorbed. Moreover, when it arrives at the surface, some of it is reflected back into the inte-
rior. The back-reflected radiation is again partially absorbed, but some of it arrives at the
other surface, through which most of it escapes; part of it is reflected back again.
Although the progressive reflections become weaker and weaker they must all be added
up when the total emittance of the plate is sought. When the resulting geometrical series
is summed, the effective emissivity of a semi-transparent plate is obtained as:
When the plate becomes opaque this formula is reduced to the single formula:
This last relation is a particularly convenient one, because it is often easier to measure
reflectance than to measure emissivity directly.
#T559954; r. AP/42311/42335; en-US
228

Table of Contents

Other manuals for FLIR T10 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FLIR T10 Series and is the answer not in the manual?

FLIR T10 Series Specifications

General IconGeneral
BrandFLIR
ModelT10 Series
CategoryThermal cameras
LanguageEnglish

Related product manuals