Calibrator
How to Contact Fluke Calibration
5
How to Contact Fluke Calibration
To contact Fluke Calibration, call one of the telephone numbers shown below.
Technical Support USA: 1-877-355-3225
Calibration/Repair USA: 1-877-355-3225
Canada: 1-800-36-FLUKE (1-800-363-5853)
Europe: +31-40-2675-200
Japan: +81-3-6714-3114
Singapore: +65-6799-5566
China: +86-400-810-3435
Brazil: +55-11-3759-7600
Anywhere in the world: +1-425-446-6110
To see product information and download the latest manual supplements, visit
Fluke Calibration’s website at www.flukecal.com.
To register your product, visit http://flukecal.com/register-product.
Specifications
The Product is verified and calibrated at the factory prior to shipment to ensure it
meets the accuracy standards necessary for all certified calibration laboratories.
By calibrating to the specifications in this section, the high-performance level can
be maintained throughout the life of the Product.
General Specifications
All specifications are valid after a warm-up period of 30 minutes, or twice the time since last warmed up, to a maximum of
30 minutes. For example, if the 5080A has been turned off for 5 minutes, the warm-up period is 10 minutes.
All specifications apply for the temperature and time period indicated. For temperatures outside of tcal ±5 °C (tcal is the
ambient temperature when the 5080A was calibrated), the temperature coefficient as stated in the General Specifications
must be applied.
The specifications also assume the 5080A is zeroed every seven days or whenever the ambient temperature changes by
more than 5 °C.
Warmup Time ......................................................... Twice the time since last warmed up, to a maximum of 30 minutes.
Settling Time ........................................................... Less than 7 seconds for all functions and ranges except as noted.
Standard Interfaces................................................. RS-232 and Ethernet
Temperature
Operating ............................................................ 0 °C to 50 °C
Calibration (tcal) .................................................. 15 °C to 35 °C
Storage ............................................................... -20 °C to +70 °C
Temperature Coefficient ......................................... Temperature coefficient for temperatures outside tcal ±5 °C is 10 % of
the stated specification per °C for temperatures in the range of 0 °C to
35 °C. Above 35 °C, the temperature coefficient is 20 % of the stated
specification per °C.
Relative Humidity
Operating ............................................................ <80 % to 30 °C, <70 % to 40 °C, <40 % to 50 °C.
Storage ............................................................... <95 %, non-condensing
Altitude
Operating ............................................................ 2,000 m (6,500 ft) maximum
Non-operating ..................................................... 12,200 m (40,000 ft) maximum
Safety ...................................................................... IEC 61010-1: Overvoltage category II, Pollution Degree 2
Analog Low Isolation ............................................... 20 V
Electromagnetic Compatibility (EMC)

Table of Contents

Other manuals for Fluke 5080A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 5080A and is the answer not in the manual?

Fluke 5080A Specifications

General IconGeneral
BrandFluke
Model5080A
CategoryTest Equipment
LanguageEnglish