Table 3-18. 75 Ω Leveling Head, High Frequency Level Accuracy Test Points (96040A and 96270A)
Amplitude Frequency Reading P
out
Tolerance
+10 dBm
100 kHz P
2
Reference
10 MHz P
3
±0.12 dB
100 MHz P
3
±0.12 dB
300 MHz P
3
±0.15 dB
1 GHz P
3
±0.25 dB
+7 dBm
100 kHz P
2
Reference
10 MHz P
3
±0.12 dB
100 MHz P
3
±0.12 dB
300 MHz P
3
±0.15 dB
1.4 GHz P
3
±0.25 dB
2 GHz P
3
±0.30 dB
-3 dBm
100 kHz P
2
Reference
10 MHz P
3
±0.12 dB
100 MHz P
3
±0.12 dB
300 MHz P
3
±0.15 dB
1.4 GHz P
3
±0.25 dB
2 GHz P
3
±0.30 dB
-13 dBm
100 kHz P
2
Reference
10 MHz P
3
±0.12 dB
100 MHz P
3
±0.12 dB
300 MHz P
3
±0.15 dB
1.4 GHz P
3
±0.25 dB
2 GHz P
3
±0.30 dB
-23 dBm
100 kHz P
2
Reference
10 MHz P
3
±0.12 dB
100 MHz P
3
±0.12 dB
300 MHz P
3
±0.15 dB
1.4 GHz P
3
±0.25 dB
2 GHz P
3
±0.3 dB
-33 dBm
100 kHz P
2
Reference
10 MHz P
3
±0.15 dB
100 MHz
P
3
±0.15 dB
300 MHz P
3
±0.20 dB
1.4 GHz P
3
±0.50 dB
2 GHz P
3
±0.50 dB
-43 dBm
100 kHz P
2
Reference
10 MHz P
3
±0.15 dB
100 MHz
P
3
±0.15 dB
300 MHz P
3
±0.20 dB
1.4 GHz P
3
±0.50 dB
2 GHz P
3
±0.50 dB