Period A, B Single
Range A, B: See Period A, B Average
Resolution: 100 ps
n
Display:
Main Parameter:
Aux. Parameters:
Period
V
max
,V
min
,V
p-p
Ratio A/B, B/A, C/A, C/B
Range: 10
-9
to 10
11
(one-pass
measurem., values < 1
with reduced resolution)
n
Input Frequency
Input A, B: 0.1 Hz - 300 MHz
Input C: See Frequency C or
Input C
n
Display:
Main Parameter:
Aux. Parameters:
Ratio
Freq 1, Freq 2
Time Interval A to B, B to A,
A to A, B to B
Range (normal
calculation):
Range (smart
calculation):
0 ns to +10
6
s
-10
6
to +10
6
Resolution
Single Shot: 100 ps
Input Frequency: Up to 160 MHz
Min. Pulse Width: 1.6 ns
Smart Calculation: Smart Time Int. w. 4 time
stamps (2 consecutive
Trig A plus 2 consecutive
Trig B) to determine sign
(A before B or A after B)
n
Display:
Main Parameter:
Aux. Parameters:
Time interval
None
Pulse Width A, B
Range: 1.6 ns - 10
6
s
Input Frequency: Up to 300 MHz
Modes: Pos. pulse width or
neg. pulse width
(depending on trigger
slope)
n
Display:
Main Parameter:
Aux. Parameters:
Pulse width
V
max
,V
min
,V
p-p
Rise and Fall Time A, B
Range: 700 ps - 1000 s
Input Frequency: Up to 160 MHz
Trigger Levels: Default 10% and 90%
Manually adjustable
Min. Pulse Width: 1.6 ns
Modes: Rise or fall time (depend
-
ing on trigger slope)
n
Display:
Main Parameter:
Aux. Parameters:
Rise or fall time
Slew rate, V
max
,V
min
Measurement Functions 8-3