VIGILUS - Operating manual
Flybox
11
Rev. 1.0
®
SECTION 1
1.1 PRIMARY ACTIONS AFTER INSTALLATION
WARNING: Do not fly until you have performed at least
the actions indicated below:
1 - Select the engine type: the first parameter to setup is the
engine selection, because it reset all the parameters to the
default value. The engine selection can be made by entering in
the Main menu Settings Global Settings Aircraft as
explained in chap.1.3.5.
2 - Tank level sensors: (if connected). It's indispensable to
perform the calibration for all the tank level sensors connected
to the Vigilus. Without performing calibration and settings no
indication will be furnished.
It is responsibility of the user to check during the first flights
and over time the goodness of the calibration and therefore
the instrument indications.
The verification can be done in any moment, for example b y
simply checking the quantity put to fill the tank: if you k n o w
that the tank filled contain 40 liters and the Vigilus i n d i c a t e
as remaining quantity 10.0 liter, you know that to fill the tank
you must put approximately 30 liters. Of course keeping in
mind that in ground the indications will be different that in
flight because of the flight's attitude. This problem is present
also in the traditional analog gauge indicators, but is more
difficult to detect because of the non-numeric indication.
Another verification is, in case of low remaining quantity (i.e.
4~5 liters), drain and measure it.