Fuel computer menu
Endurance Alm = ON/OFF: Enable or disable the alarm on
endurance (default=ON).
Min Time: Set the minimum time, in minutes, for the “Endurance
Alm”. When the endurance indication of the Fuel Computer is
below this setpoint the alarm is activated (range: 0~999 min,
default=30 min).
Endurance Rep: Set the number of times that the vocal alarm
for the endurance is repeated on the audio output (range:1~5,
default=1).
Balance Alm = ON/OFF: Enable or disable the alarm for tanks
balance (default=ON).
Bal. Q.ty: Set the fuel quantity for the “Balance Alm”. If the
“Balance Alm” is enabled, the Vigilus will activate an alarm
every time the quantity of fuel used equals this value, showing
“TANK BALANCE” on the display.
This function is useful to keep balanced two wing tanks,
switching from one to the other after using a certain quantity
of fuel (range: 0.1~99.9 lt, default=10.0 lt).
Balance Rep: Set the number of times that the vocal alarm for
the tanks balance is repeated on the audio output (range:1~5,
default=1).
1.3.7 ABOUT MENU:
On this screen it’s possible to read current firmware versions,
useful to check if your Vigilus and remote module are updated
to the latest versions.
NOTE: This manual is referred to the Vigilus firmware version
indicated on the first page.