Factory default configuration is for ROTAX 912
A/F/S/UL/ULS/ULSFR engine:
Measure
BOTTOM
LIMIT
LOW
YELLOW
SETPOINT
GREEN
SETPOINT
HIGH
YELLOW
SETPOINT
RED
SETPOINT
TOP
LIMIT
CHT (°C) 50 75 130 150
EGT (°C) 650 850 880 930
OIL temp. (°C)
30 45 90 130 150
OIL press.
(BAR)
0 0.8 20 50 7.0 9.0
CAT (°C) 0 45 100
OAT (°C) 0 100
RPM 0 5500 5800 6200
MAP 0 50 50 50
Fuel press.
(BAR)
0.00 0.15 0.40 0.50
Voltage (V) 10 11.5 15 16
Current (A) -50 50
For ROTAX 914 F/UL engine the only difference of the default
values is the EGT:
EGT (°C) 850 950 950 1000