Oil temp. setup menu
Repeat: Set the number of times that the vocal alarm for the
oil temp. is repeated on the audio output (range:1~5, default=1).
Auto reset = ON/OFF: if set to ON, if a alarm condition is
activated but the measurement has returned in the safe zone,
the Vigilus automatically reset the alarm indication. If set to
OFF, the user must manually reset the alarm indication, even
if the measurement has returned in the safe zone (default=ON).
Out map: you can choose to enable one of the four outputs
available on the remote module when the alarm is activated,
useful for example to turn on an alarm light on the cockpit.
Set to zero to disable this function (default=0).
Type: set the type of oil temperature sensor installed:
NO: not installed (disable the indication).
ROX: standard ROTAX oil temperature sensor (default) .
JAB: standard JABIRU sensor.
P1K: PT1000 resistive sensor.
Clearance: setpoint to allow warming the oil before takeoff
(used for the WARMUP/READY status indicator).
Range:0~999°C, default=50°C.
Unit: °C / °F: Set the unit of measure for the oil temperature;
choose between °Celsius (°C) or °Fahrenheit (°F).Default=°C.
Filter: This parameter affect the readings and the gauges
displayed: a low value means that the readings will be more
fast and unfiltered (but subject to fluctuations), an high value
means that the readings will be more slow and stable (range:
0~999, default=100).
Instrument configuration