Control elements and connections
Indications/
controls on the
device
Function key
1x WPS
2x ACCESS POINT
3x BOOST MODE
Press 1x WPS (Wi-Fi Protected Setup) opens
for 2 minutes or until successful
pairing with the router. Pressing the
WPS button on the router sends the
WLAN password to the Ohmpilot.
Press 2x WLAN access point is activated for
30 minutes so that settings can be
implemented on the Ohmpilot via
the Fronius Solar.web app.
Press 3x Boost mode - dimmer level is activ-
ated at 100% for 4 hours, switching
takes place through phases 2 and 3.
This may result in electricity being
sourced from the grid.
Press again Ohmpilot is returned to the standard
operating mode; boost mode, access
point or WPS are deactivated.
Press for 7
seconds
Ohmpilot restarts
Heater indica-
tion
Unlit No power supply to the Ohmpilot.
Flashing green
(permanently)
The faster the flashing frequency,
the greater the heat output. The LED
flashes slowly at 0 W heat output
and quickly at full output.
Flashing green
(twice)
The heating element output is being
measured. The Ohmpilot recognises
whether a 1-phase or 3-phase heat-
ing element is connected.
Lights up
green
Minimum temperature undershot or
Legionella prevention system active
(full heat output).
12