The temperature is measured by the Ohmpilot. If the temperature falls below the
minimum, then an external source (e.g. gas-fired heating) will be activated until
the minimum temperature is reached again, so that the Ohmpilot only uses sur-
plus energy and does not draw any energy from the grid.
The maximum temperature must be set on the heating element thermostat. If
the heating element does not have a thermostat, the Ohmpilot can also carry out
this task as an alternative (see "Optional settings" section Optional settings on
page 45).
The heating element is used for the Legionella prevention program.
This function can also be combined with a 3-phase heating element.
Settings in the
menu area
General settings, symbolic representation
1
Open the Ohmpilot user interface (see section Establishing the data connec-
tion).
2
Enable the "Temperature sensor present" field
3
Enable the "Adapt day curve" field
4
Set the settings under "Time from", "Time to" and "Minimum temperature" as
required
For more information, see section Adapting the day curve
5
Under HEATER 2, select "Activate external source" for Consumer