66
The insulation resistance is the resistance between the positive or negative pole of the 
photovoltaic system and the ground potential. If an insulation resistance > 500 kilohms is 
shown, this means that the photovoltaic system is adequately insulated.
An insulation resistance of less than 500 kilohms indicates an error.
When the insulation resistance is less than 10 megaohms, the display differentiates be-
tween:
- negative potential of the ground (polarity sign '-')
- positive potential of the ground (polarity sign '+')
Display values for 
a total system in 
the 'Now' display 
mode
The Fronius Personal Display DL can show the following power data in the 'Now' display 
mode for a total system:
Display example of a negative potential 
(polarity sign '-')
Short circuit between DC- lead and 
ground
Display example of a positive potential 
(polarity sign '+')
Short circuit between DC+ lead and 
ground
Date
When the date on the inverter or a system 
upgrade is changed, this changes the 
date on all devices connected via Solar 
Net.
Time
When the time on the inverter or a system 
upgrade is changed, this changes the time 
on all devices connected via Solar Net.
Output power
Power (in Watts) currently being fed into 
the grid
Date
When the date on the inverter or a data 
communication component is changed, 
this changes the date on all devices con-
nected via Solar Net.
Time
When the time on the inverter or a data 
communication component is changed, 
this changes the time on all devices con-
nected via Solar Net.