80
Remedy: Check inverter numbers and correct if necessary according to
the inverter operating instructions.
Cause: The inverter is not in range of the wireless connection.
Remedy: Check the wireless connection range
Cause: There is a one-sided wireless pairing between a Fronius Per-
sonal Display Card and the Fronius Personal Display DL
Remedy: Reset the Fronius Personal Display Card in the inverter
The Fronius Personal Display DL does not find a Fronius Personal Display DL Box
in 'ADD IG' search mode
Cause: There is a one-sided wireless pairing between a Fronius Per-
sonal Display DL Box and the Fronius Personal Display DL
(e.g., after replacing the Fronius Personal Display)
Remedy: Select the 'ADD IG' menu item in the Setup menu of the
Fronius Personal Display DL
Disconnect and then reinsert the Solar Net cable at the Fro-
nius Personal Display DL Box
Press the 'Enter' key within 10 seconds on the Fronius Per-
sonal Display DL
ADD IG --
(for 'ADD IG' search mode)
Cause: DC power to the inverter has been interrupted.
Remedy: Check the DC-side inverter power supply.
Cause: Old firmware version for inverter
Remedy: Update the firmware
ERROR IGxx
(for 'ADD IG' search mode)
Cause: The address number assigned to the inverter is higher than 15.
Remedy: Check inverter number and correct if necessary according to
the inverter operating instructions.
ERROR BATT
Power supply unit plugged in, battery charging operation
Cause: Incorrect or faulty batteries were inserted.
Remedy: Check batteries
FULL LIST
(for 'ADD IG' search mode)
Cause: 15 Fronius inverters are already integrated into the system.
1