Overloading of the tungsten electrode
Overloading of
the tungsten elec-
trode
Possible causes of tungsten electrode overload:
- tungsten electrode diameter is too small
- main current value I
1
set too high
Remedy:
- use a tungsten electrode with a larger diameter
- reduce the main current
IMPORTANT! The "Electrode overload" indicator is designed to work with ceriated elec-
trodes. For all other electrodes, the "Electrode overload" indicator must be treated as a ref-
erence value.
If the tungsten electrode is overloaded, the "Electrode overload" indicator on the
control panel lights up.