Troubleshooting
General The power source is fitted with an intelligent safety system that allows fuses to be dis-
pensed with entirely. After a possible malfunction or error has been remedied, the power
source can be put back into normal operation again without any fuses having to be re-
placed.
Safety
Displayed service
codes
If any error message that is not described here appears on the displays, then the fault can
only be fixed by a service technician. Make a note of the error message shown in the dis-
play and of the serial number and configuration of the power source, and contact our After-
Sales Service team with a detailed description of the error.
WARNING! An electric shock can be fatal. Before opening the device:
- Move the mains switch to the "O" position
- Unplug the device from the mains
- Put up an easy-to-understand warning sign to stop anybody inadvertently
switching it back on again
- Using a suitable measuring device, check that electrically charged parts (e.g.
capacitors) have been discharged
CAUTION! Inadequate PE conductor connections can cause serious injury and
damage. The housing screws provide a suitable PE conductor connection for
earthing (grounding) the housing and must NOT be replaced by any other screws
which do not provide a reliable PE conductor connection.
tS1 | xxx
Cause: Overtemperature in the secondary circuit of the power source
(xxx stands for a temperature value)
Remedy: Allow power source to cool down
Err | tS1
Cause: temperature sensor faulty (short circuit or break)
Remedy: Contact After-Sales Service
no | IGn
Cause: Ignition time-out function is active: there was no current before
the end of the time specified in the Setup menu. The safety cut-
out of the power source has been triggered.
Remedy: Press the torch trigger repeatedly; clean the workpiece surface;
if necessary, increase the time until the safety cut-out is trig-
gered in Setup menu: level 2.
no | Arc
Cause: Arc break
Remedy: Press the torch trigger repeatedly; clean the surface of the
workpiece
Err | IP

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius TransTig 1750 Puls and is the answer not in the manual?

Fronius TransTig 1750 Puls Specifications

General IconGeneral
BrandFronius
ModelTransTig 1750 Puls
CategoryWelding System
LanguageEnglish

Related product manuals