73
EN
Rod electrode setup menu: level 2
Accessing the
Rod electrode
setup menu level
2
Changing weld-
ing parameters
Exiting the Rod
electrode setup
menu: level 2
Welding parame-
ters in the Rod
electrode setup
menu level 2
Accessing the Rod electrode setup menu
Select "2nd" welding parameter
Press and hold the Mode button
Press the Parameter Selection button (right)
The power source is now in the Rod electrode setup menu: level 2. The
last parameter selected is displayed.
2
3
4
Use the left or right Parameter Selection button to select the param-
eter that you want to change
Use the adjusting dial to change the parameter value
1
2
Press the Mode button
The power source is now in the Rod electrode setup menu.
To exit from the Rod electrode setup menu, press the Mode button
again
1
2
ASt
Anti-stick
Unit -
Setting range ON / OFF
Factory settings ON
As the arc becomes shorter, the welding voltage may drop so far that the rod electrode
will tend to stick. This may also cause the rod electrode to burn out.
Electrode burn-out is prevented by activating the anti-stick function. If the rod electrode
begins to stick, the power source immediately switches the welding current off. After the
rod electrode has been detached from the workpiece, the welding process can be contin-
ued without any problems.
Uco
U (voltage) cut-off - welding voltage limitation