80
Care, maintenance and disposal
General Under normal operating conditions, the power source requires only a minimum of care and
maintenance. However, it is vital to observe some important points to ensure it remains in
a usable condition for many years.
Safety
At every start-up - Check mains plug, mains cable, welding torch, interconnecting hosepack and ground-
ing (earthing) connection for damage
- Check that there is a gap of 0.5 m (1 ft. 8 in.) all around the device to ensure that cool-
ing air can flow and escape unhindered
Every 2 months - If present: clean air filter
Every 6 months - Dismantle device side panels and clean inside of device with dry reduced compressed
air
- If a lot of dust has accumulated, clean the cooling air ducts.
Disposal Dispose of in accordance with the applicable national and local regulations.
WARNING! An electric shock can be fatal. Before opening the device
- Turn the mains switch to the "O" position
- Unplug the machine from the mains
- Prevent it from being switched on again
- Using a suitable measuring instrument, check to make sure that electrically
charged components (e.g. capacitors) have discharged
WARNING! Work that is carried out incorrectly can cause serious injury and dam-
age. The following activities must only be carried out by trained and qualified per-
sonnel. All instructions in the section headed "Safety rules" must be observed.
NOTE! Air inlets and outlets must never be covered, not even partially.
NOTE! Risk of damage to electronic components. Do not bring air nozzle too
close to electronic components.