EasyManua.ls Logo

Fronius TransTig 1750 Puls - Page 81

Fronius TransTig 1750 Puls
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
79
EN
Remedy: Change the gas cylinder
Cause: Gas pressure regulator is faulty
Remedy: Change the gas pressure regulator
Cause: The gas hose is not fitted or is damaged
Remedy: Fit/change the gas hose
Cause: The welding torch is faulty
Remedy: Change the welding torch
Cause: Gas solenoid valve is faulty
Remedy: Replace gas solenoid valve
Poor weld properties
Cause: Incorrect welding parameters
Remedy: Check the settings
Cause: Grounding (earthing) connection is incorrect
Remedy: Check the earth (ground) connection and clamp for correct po-
larity
The welding torch becomes very hot
Cause: The design dimensions of the welding torch are not sufficient for
this task
Remedy: Observe the duty cycle and loading limits

Table of Contents

Related product manuals