4
Use the adjusting dial to select the corresponding push-pull unit:
5
Press the right arrow key
The third push-pull calibration screen is shown:
6
Follow the instructions shown
CAUTION!
Risk of injury from rotating cogs and drive parts.
Keep hands away from rotating cogs and the wire drive parts.
7
Press the right arrow key
The fourth push-pull calibration screen is shown:
8
Follow the instructions shown
CAUTION!
Risk of injury from welding wire emerging and from rotating cogs and drive parts.
Keep the welding torch away from your face and body.
Keep hands away from rotating cogs and the wire drive parts.