Page #194 background image
Every 6 months
CAUTION!
Danger due to the effect of compressed air.
This can result in damage to property.
Do not bring the air nozzle too close to electronic components.
1
Dismantle device side panels and clean inside of device with dry, reduced com-
pressed air
2
If a lot of dust has accumulated, clean the cooling air ducts
WARNING!
An electric shock can be fatal!
Risk of electric shock from improperly connected ground cables and equipment grounds.
When reassembling the side panels, make sure that grounding cables and equip-
ment grounds are properly connected.
Disposal Dispose of in accordance with the applicable national and local regulations.
194