HotStart time
Unit s  
Setting range 0 - 2,0  
Factory setting 0,5  
To obtain optimum welding results, it will sometimes be necessary to adjust the hot-
start function.
Advantages:
- Improved ignition, even when using electrodes with poor ignition properties
- Better fusion of the base material in the start-up phase, meaning fewer cold-shut
defects
- Largely prevents slag inclusions
 
Rod elec. setup 2nd
Second level of the rod electrode setup
136