Make sure to attach the rack rails to rack pillars so that they fit exactly together without any space
between them.
(Rack pillar: front)
(Rack pillar: rear)
Washer
M5 screw
M5 screw
Washer
M5 screw
Plate
M5 screw
Plate
Rack rail (right)
Rack rail (left)
The M5 screw positions for the rack rails are determined by the controller enclosure base line.
Insert the M5 screws in the 1st and 6th holes on the front rack pillars above the base line and in the
2nd and 5th holes on the rear rack pillars above the base line to fasten the rack rails.
Controller enclosure: front
Controller enclosure: rear
2U
Rack rail
Controller
enclosure base line
Rack rail
Controller
enclosure base line
[Right]
[Left]
6th hole
(M5 screw)
1st hole
(M5 screw)
6th hole
(M5 screw)
1st hole
(M5 screw)
2U
[Right][Left]
5th hole
(M5 screw)
2nd hole
(M5 screw)
5th hole
(M5 screw)
2nd hole
(M5 screw)
3 Tighten the M4 screws of the rack rails that were slightly unscrewed in Step 1.
Chapter 2
Rack Installation
2.2 Controller Enclosure Installation (for Regions Other than EMEA&I)
33
FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Configuration Guide (Basic)
Copyright 2014 FUJITSU LIMITED
P3AM-7652-02ENZ0