• Do not use the RMT port for an operation management LAN. Use the RMT port only for remote sup-
port.
• Configure the IP address for the MNT port with an IP address in a different subnetwork than the
RMT port.
• When specifying the IP address of the Slave CM, specify an IP address that is in the same subnet
but is different from the IP address of the Master CM.
• Either or both an IPv4 address and an IPv6 address can be specified for the MNT port and the RMT
port.
(1) Click the [IPv4 Settings] tab to specify an IPv4 address. Click the [IPv6 Settings] tab to specify an
IPv6 address.
The following procedure shows an example when selecting the [IPv4 Settings] tab.
A confirmation screen appears.
(2) Click the [OK] button.
The network environment setting is applied and the setting completion screen appears.
(3) Click the [Done] button.
The [Logout] screen appears.
Chapter 5
General Settings
5.4 Storage Management (Initial Setup 1)
83
FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Configuration Guide (Basic)
Copyright 2014 FUJITSU LIMITED