Do not use the RMT port for an operation management LAN. Use the RMT port only for remote sup-
port.
Configure the IP address for the MNT port with an IP address in a different subnetwork than the
RMT port.
When specifying the IP address of the Slave CM, specify an IP address that is in the same subnet
but is different from the IP address of the Master CM.
Either or both an IPv4 address and an IPv6 address can be specified for the MNT port and the RMT
port.
(1) Click the [IPv4 Settings] tab to specify an IPv4 address. Click the [IPv6 Settings] tab to specify an
IPv6 address.
The following procedure shows an example when selecting the [IPv4 Settings] tab.
A confirmation screen appears.
(2) Click the [OK] button.
The network environment setting is applied and the setting completion screen appears.
(3) Click the [Done] button.
The [Logout] screen appears.
Chapter 5
General Settings
5.4 Storage Management (Initial Setup 1)
83
FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Configuration Guide (Basic)