30 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1121 February 2016
RTIF1-
070914-001
O O While executing the firmware update
by using the flashupdate(8)
command or BUI, when the import of
XCP executed by using the
getflashimage(8) command or BUI,
the firmware update aborts.
Do not execute the import of XCP by
using the getflashimage(8)
command or BUI, while executing the
firmware update.
RTIF1-
070914-002
O O When the XSCF switching performed,
the monitor message doesn't show the
number of XSCF unit which turned
active.
Execute the showhardconf(8)
command to refer to the state of XSCF
unit.
RTIF1-
070914-003
O O When the XSCF switching performed,
there may be "SCF: Board control
error (DMA timeout)" stored in
the error log.
No workaround is available.
This message can be safely ignored.
RTIF1-
070914-005
O O On the XSCF Web, when using
Internet Explorer 7, on the [User
Accounts] screen, User Local
Accounts doesn't show the Status of
each user.
None available at this time.
RTIF1-
070914-006
O O When you set the XSCF user account
name to the maximum 32 characters,
you can log in, but then, when you
execute the XSCF Shell or operate the
XSCF Web, "Permission denied"
occurs.
Use up to 31 characters to set the
XSCF user account name.
RTIF1-
070914-007
O O On the XSCF Web, when you use
Internet Explorer and select [Log
Archives], the [Status of Log
Archiving] screen doesn't show the
status information.
None available at this time.
RTIF1-
070914-008
O O On the XSCF Web, when you select
[POP] or [SMTP-auth] on the [SMTP]
screen to enter Password, the input
value doesn't appear as "*".
None available at this time.
RTIF1-
070914-009
O O On the XSCF Web, when selected
[POP] or [SMTP-auth] on the [SMTP]
screen, the setting can be done while
the input field remains blank. And
despite the setting done, the past
setting data appears.
None available at this time.