Chapter 3 Information About Software 43
RTIF1-
090108-004
O When you replaced the XSCF unit by
using the replacefru(8) command,
there may be the DB
synchronization timeout error
log and the replacement may fail.
Turn off all mainline switches and
then turn on again.
Or, just after the XSCF reset using the
rebootxscf(8) command, execute
the replacefru(8) command and
extract and insert the XSCF unit
which failed in replacement. If time
passed after the XSCF reset, the
replacefru(8) command may fail
again. In such a case, re-execute the
rebootxscf(8) command and the
subsequent processes.
RTIF1-
090115-001
OOOWhen you execute the settelnet -
c disable command, the Telnet
service will be stopped immediately.
However, unless you reset XSCF by
using the rebootxscf(8) command,
you might fail in the subsequent
restart of the Telnet service.
After you stopped the Telnet service,
execute the rebootxscf(8) command
to reset XSCF.
RTIF1-
090122-001
OOO"Power recovery" message is
output before a PSU has recovered.
After the "Power recovery"
message is output, wait 60 seconds
before removing power from another
PSU.
RTIF1-
090220-001
OOOIn a system connecting multiple hosts
and one or more I/O units with RCI,
the power-on operation to one of
those RCI hosts may not power on
any of the RCI I/O units.
All the RCI hosts shall be powered on.
TABLE 3-3 XCP Issues Fixed in Releases Earlier Than XCP 1121 (Continued)
ID M3000
M4000
M5000
M8000
M9000 Description Workaround