44 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1121 • February 2016
RTIF1-
090220-002
OOOM3000 server:
After replaced the motherboard unit,
the RCI power interlocking setting
restores to its default value.
M4000/M5000/M8000/M9000
servers:
After replaced the XSCF unit, the RCI
power interlocking setting restores to
its default value.
M3000 server:
If you have set the power interlocking
to a value other than the default,
replace the motherboard unit and
then use the setpwrmode(1M)
command to set the power
interlocking setting again.
M4000/M5000/M8000/M9000
servers:
If you have set the power interlocking
to a value other than the default,
replace the XSCF unit and then use
the setpwrmode(1M) command to set
the power interlocking setting again.
RTIF1-
090427-001
OOODespite the normal status of ppp
network interface for the XSCF-to-
Oracle Solaris OS communication,
SNMP MIB notifies abnormal (down)
status.
No workaround is available.
RTIF1-
090427-002
OOOAfter the XSCF reset or switching, you
cannot login to XSCF using the LDAP
server.
No workaround is available.
Log in to active XSCF with initial
account and execute the following
command to re-import the certificate
chain.
'setldap -c <remote file>'
RTIF1-
090427-003
O After changed the SNMP
configuration, when the XSCF
switching occurred, the SNMP
function may be disabled.
No workaround is available.
In case this event occurred, the
following command may restore the
function.
setsnmp disable
setsnmp disable (run "setsnmp
disable" twice)
setsnmp enable
RTIF1-
090427-004
OOOIn the setting of the LDAP server, the
number of characters which can be
specified differs between XSCF Web
and XSCF Shell. On XSCF Web, you
can enter up to 128 characters.
To set 129 characters or more, use
XSCF Shell.
TABLE 3-3 XCP Issues Fixed in Releases Earlier Than XCP 1121 (Continued)
ID M3000
M4000
M5000
M8000
M9000 Description Workaround